Containerized Diesel Generator Sets|500kW-3000kW+ ISO Power Station
Technical Features
ISO Standard Containers: 20ft & 40ft options, external 6058×2438×2591mm / 12192×2438×2591mm; internal 5900×2300×2350mm / 12032×2352×2385mm.
High Capacity Power: Continuous power 500kW–3000kW+, Prime & Standby ratings for industrial loads.
Soundproof Design: Fully attenuated, 65–75 dB at 7m distance, suitable for urban and industrial sites.
Weatherproof & Corrosion Resistant: IP23–IP44 rated, hot-dip galvanized base frame, anti-corrosion paint.
Integrated Control & Fuel Systems: Smart DeepSea/ComAp controller, large capacity diesel tank for 24–72h autonomy.
Rapid Deployment & Transportable: Plug & play, forklift and crane lifting points, optimized for sea freight.
Engine & Alternator Flexibility: Cummins/Perkins engines, Stamford/Leroy Somer alternators, customized load matching.
Safety & Compliance: Fire-resistant cables, vibration dampers, emergency shutdown, CE/ISO certified.

Main Technical Parameters
Technical Parameter |
20ft Containerized Specification |
40ft Containerized Specification |
Power Output (Prime/Standby) |
500 kW – 1250 kW / 625 kVA – 1562 kVA |
1250 kW – 3000 kW+ / 1562 kVA – 3750 kVA+ |
Engine Brands Available |
Cummins / Perkins / MTU / Mitsubishi |
Cummins / Perkins / MTU / Baudouin |
Alternator Brands Available |
Stamford / Leroy Somer / Marathon |
Stamford / Leroy Somer / Mecc Alte |
Control & Sync System |
DeepSea 7310 / ComAp InteliLite |
DeepSea 8610 (Auto Paralleling & Load Share) |
Noise Level @ 7m |
70 – 75 dB(A) (Custom low-noise to 65 dB) |
72 – 78 dB(A) (Custom low-noise to 68 dB) |
External Dimensions (L×W×H) |
6058 × 2438 × 2591 mm |
12192 × 2438 × 2591 mm |
Internal Dimensions (L×W×H) |
5900 × 2300 × 2350 mm |
12032 × 2352 × 2385 mm |
Enclosure / Alternator IP Class |
IP54 Enclosure / IP23 Alternator |
IP54 Enclosure / IP23 Alternator |
Surface Coating Standard |
C4 Standard / C5 Marine Optional |
C4 Standard / C5 Marine Optional |
Base Fuel Tank Capacity |
Integrated 8 – 12 Hours Runtime |
Integrated 8 – 24 Hours Runtime / External Connection |
Quality
Testing Protocol: 100% of units are subjected to factory inspection before shipment, covering 0%, 25%, 50%, 75%, 100%, and 110% load testing to verify transient response and oil/water temperature stability.
Certification: Manufacturing processes align with ISO9001 and ISO14001, with full CE compliance. Third-party testing (SGS/Intertek) is available upon request.
Warranty: 12 months or 1000 running hours from commissioning, backed by standard maintenance parts supply.
Get Your Free Sizing: Send your single-line diagram (SLD), preferred engine brand, and site environmental parameters. Our technical sales team will provide an general arrangement layout and CIF quotation.
Component Engineering Flexibility
Engines
Cummins (global parts network), Perkins (proven mechanical/electronic injection), or MTU (heavy continuous load stability).
Alternators
Stamford, Leroy Somer, or Marathon—featuring 100% copper windings, Class H insulation, and standard AVR.
Control Panels
DeepSea (DSE series) or ComAp controllers setup for AMF (Automatic Mains Failure), remote telemetry, and multi-unit paralleling (N+1 grids).
Applications
Data Centers:
Tier-3/Tier-4 emergency standby power with automated synchronization upon utility failure.
Mining & Extraction:
Open-pit prime power under high-dust, high-vibration, and fluctuating load conditions.
Infrastructure Projects:
Grid-independent power for isolated ports, construction sites, and municipal water works.
Case Study:
Hybrid Power Deployment for an Off-Grid Exploration Camp
Client Requirement: A remote exploration camp operating 24/7 was dependent on a standard diesel genset running constantly, leading to high fuel delivery costs and continuous exhaust noise.
Our Configuration: Designed a Containerized Hybrid Station integrating a 30kWp deployable solar array, a 120kWh LiFePO4 battery room, and a 50kW Cummins auxiliary diesel generator with an automated EMS relay panel.
Operational Result: Auxiliary engine run times dropped from 24 hours down to an average of 2.5 hours per day, activating only during prolonged cloudy periods or peak load conditions. Fuel use decreased by 78%, lowering site operating costs and eliminating nighttime engine noise.
Send Inquiry
We are committed to providing you with the best quality service and look forward to communicating with you to solve problems together and bring you a better experience.